6. Attach low voltage thermostat No. 18 up to 30 ft.
run No. 16 to 15ft. Run (purchase locally) to ter-
minal plate, screws identified with letters G & R.
(Generally top row center, bottom row right).
Snake wire through holes in top of box. Replace
outer covers & control knob. Under no circum-
stances should you attempt to plug in main power
cord until all wiring and covers are in place.
NOTE: A ground power cord plug is provided;
however, local codes may require fuse box
mounting.
8. Install top shroud (if removed) by simply placing
shroud on to the top of unit, push down, check
each corner for snug fit.
Attaching furnace control center box. To sepa-
rate outer cover, remove two (2) side screws and
pull off black rheostat knob. Attach box to left
side (facing feed door) with four (4) self-thread-
ing screws. One screw in each corner. (NOTE:
Furnace control center is designed for left side
attachment. Should space prohibit such, revers-
ing shrouds for right side installation is possible,
however, control wires from box will have to be
extended.)
Next, attach the 4x4 junction box below the con-
trol center box, using (2) self-threading screws pro-
vided in the parts bag. (Two starter holes are
provided.)
5a.
5b.
Wall thermostat should be mounted on an up-
stairs inside wall (no outside facing wall) prefer-
ably near your existing thermostat. For more spe-
cific information, read the Honeywell instruction
sheet provided with thermostat. Caution: discon-
nect the power supply before installing. NOTE:
Your wall thermostat and transfer relay are mated
Honeywell products for trouble free installation.