Stanley Black & Decker AL35 Automobile Parts User Manual


 
AL35 User Manual ◄ 13
Make sure all couplers are wiped clean before con-
nection.
The hydraulic circuit control valve must be in the
“OFF” position when coupling or uncoupling hydrau-
lic tools. Failure to do so may result in damage to
the quick couplers and cause overheating of the hy-
draulic system.
Always store the tool in a clean dry space, safe from
damage or pilferage.
Make sure the circuit PRESSURE hose (with male
quick disconnect) is connected to the “IN” port. The
circuit RETURN hose (with female quick disconnect)
is connected to the opposite port. Do not reverse cir-
cuit ow. This can cause damage to internal seals.
Always replace hoses, couplings and other parts
with replacement parts recommended by Stanley
Hydraulic Tools. Supply hoses must have a mini-
mum working pressure rating of 2500 psi/172 bar.
Do not exceed the rated ow (see Specications) in
this manual for correct ow rate and model number.
Rapid failure of the internal seals may result.
Always keep critical tool markings, such as warning
stickers and tags legible.
Do not force a small breaker to do the job of a large
breaker.
NOTICE
In addition to the Safety Precautions found in
this manual, observe the following for equipment
protection and care.
Keep tool bit sharp for maximum breaker perfor-
mance. Make sure that tool bits are not chipped or
rounded on the striking end.
Never operate a breaker without a tool bit or without
holding it against the work surface. This puts exces-
sive strain on the breaker foot.
Tool repair should be performed by experienced
personnel only.
Make certain that the recommended relief valves
are installed in the pressure side of the system.
Do not use the tool for applications for which it was
not intended.
TOOL PROTECTION & CARE