Page 22 - ASTRA/G55
locking and unlocking. Program to 3 seconds for vehicles equipped with vacuum door locking systems.
0.1 seconds for vehicles that roll windows up or down when lock/unlock output is at 1 second.
10. Passive Door Locking. Selects whether or not the system will automatically lock the doors during
Passive Arming.
11. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with a
residual dome light circuit that remains on for a period of time after closing the door.
12. Auxiliary 1 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 1.
Momentary operation provides an output for as long as the transmitter button is pressed.
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and remains
on until the transmitter button is pressed again.
13. Disarm with Auxiliary 1. When selected, activating the Auxiliary 1 output (usually used to open the
trunk) will disarm the alarm.
14. Starter Confirmation Chirps. When Enabled, siren will chirp to confirm Starter Active state.
Enable Auxiliary Start Activation. Enable to use the axillary start feature if used in keless entry
mode.
15. Start in Valet Mode. Selects whether or not the vehicle can remote start while in the valet mode.
16. Lock After Start. When selected, the doors will automatically lock after remote starting.
17. Lock After Shutdown. When selected, the doors will automatically lock after remote shutdown.
18. Engine Run Time. Selects between 15 or 25 minutes for the remote start run cycle.
19. Automatic Start Mode. Selects between every two hours or every hours for the automatic engine
starting feature.
20. Tachless Sense Crank Time. Selecting engine crank time automatically selects the tachless mode
and one of three crank times.
If the normal engine crank time is too short increase the time by selecting one of the two additional
extended crank time options.
Normal - 0.8Sec.
Extended - 1.0Sec.
Super Extended - 1.4Sec.
T
achless Mode. Determines the engine status using an advanced software routine, without requiring
connection to the vehicle’s tachometer. Tachless operation may not be compatible with some vehicles
or in severe temperatures, in which case the tach wire must be connected.
21. Remote Start Program. This dual program branch sets the engine mode for Gas or Diesel, and
learns the vehicle’s RPM threshold. Learning the RPM threshold automatically selects the RPM monitor
mode. For installation into a diesel equipped vehicle, first set the engine type to diesel before learning
RPM.
T
ach Monitor Mode. Monitors the vehicle’s tach wire (or a fuel injection wire) in real-time to determine
engine status and adjust starter crank time automatically. If programmed for Tach Monitor, the vehicle’s
tach signal will have to be learned before initial operation (see below).