Scytek electronic 4000RS Automobile Alarm User Manual


 
Branch Feature Button 1 (default) Button 2 Button 3
1. Arm Mode Manual Arming Passive Arming
2. Auto Rearming Mode Disabled Enabled
3. Arming Chirps Siren Chirps On Silent Siren & Horn Chirps On
4. Warn-Away Pager Report Enabled Disabled
5. Extended Parking Lights On Off
6. Ignition Door Locking On Off Set Override Code
7. Ignition Door Unlocking On Off
8. Door Unlock Pulse Single Double Pulse Ignition Before unlock
9. Door Lock Pulse Length 1 second 3 seconds 0.1 seconds
10. Passive Door Locking Disabled Enabled
11. Ignore Open Door Report Report Ignore
12. Aux 1 Mode Pulsed Timed Latched
13. Disarm with Aux 1 Disabled Enabled
14. Starter Confirmation Chirps Disabled Enabled Enable Auxiliary Start Activation
15. Lock after Start On Off
16. Lock after Shutdown On Off
17. Engine Run Time 15 minutes 25 minutes
18. Automatic Start Mode 2 hours 1 hour
19. Tachless Sense Crank Time Normal Extended Super Extended
20. Engine Sense Mode Smart Start Smart Start Monitor Disabled Data Bus RPM
21. Remote Start Program RPM Mode/RPM Learn Gas Engine Diesel Engine
22. Ignition 2 Output Program Ignition 2 Output Accessory 2 Output Starter 2 Output
23. Astra 1000/G55 External Start One Pulse Three Pulses
24. Siren Mode Normal Siren MP Player Siren
25. Astra 1000/G55 Turbo Mode Off On
26. Data Bus Input Trigger Enabled Disabled
27. Horn Chirp Duration Normal Extende Super extended
28. Factory Rearm Output Normal Ground Out When Running (2)
29. Astra System Mode ASTRA 1000 ASTRA 4000
ASTRA/G55 - Page 21
Locking, and programs the optional Emergency Override Code.
Ignition Door Locking. Selects whether or not the system will automatically lock the doors 5 seconds
after the ignition key is turned on.
Ov
erride Code Set. Changes the Emergency Override Code for a higher level of security.
7. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when
the ignition is turned off.
8. Door Unlock Pulse. Selects between one pulse or two pulse operation for the door unlock output.
Many new import vehicles’ factory door locking systems require two pulses on the proper wire to unlock
the doors. These systems can be interfaced directly without the use of relays or any additional circuitry
by programming the system for double unlock pulse. also programs to pulse the ignition before unlock
9. Door Lock Pulse Length. Selects between a 1-second, 3-second or 0.1 second output for door