Scytek electronic 2200 Automobile Alarm User Manual


 
Precision - Page 25
plugs are warm before cranking the starter. If the glow plug wire is not connected, the built-in timer
waits 15 seconds before automatically cranking the starter.
22. Ignition 2 Relay Program. Selects one of three operating modes for the Ignition 2 relay output:
Ignition 2, Accessory 2, or Starter 2.
23. Horn Output. When set for Horn Output the horn wire will pulse when the alarm is triggered. When
Ignition 3 Output is selected, the output will activate during remote start to trigger a relay for Ignition 3.
24. Turbo Timer. When enabled, if the emergency brake has been applied Ignition power will be kept On
for a predetermined time (2 minutes Factory Default) from the application of the emergency brake.
25. Extended Parking Lights. When Enabled, upon Disarming Parking lights will turn On for 30 seconds
26. Warn-Away Pager Report. When Enabled, Warn-Away report will be sent to the pager. If Disabled
no Warn-Away report will be sent to the pager.
System
Options
for
2200
Series
Branch Feature Button 1 (default) Button 2 Button 3
1. Ignition Door Locking On Off
2. Ignition Door Unlocking Unlock All Unlock Driver Only Off
3. Door Unlock Pulse Single Double
4. Door Lock Pulse Length 1 second 3 seconds
5. Aux 2 Activate on Lock Off On
6. Aux 2 Mode Pulsed Timed Latched
7. Unlock with Aux 1 Disabled Enabled
8. Aux 3 Mode Aux 3 Output Factory Rearm Output
9. Start in Valet Mode Disable Enabled
10. Lock after Start On Off
11. Lock after Shutdown On Off
12. Engine Run Time 15 minutes 25 minutes
13. Automatic Start Mode 2 hours 1 hour
14. Engine Sense Mode Tachless
15. Remote Start Program RPM Learn Gas Engine Diesel Engine
16. Ignition 2 Output Program Ignition 2 Output Accessory 2 Output Starter 2 Output
17. Horn Honk Output Horn Output Ignition 3 Output
18. Turbo Mode Disabled Enabled
19. Extended Parking Lights On Off
20 Horn Honk Mode Normal Extended
21 Key-Less Entry Honks Enabled Disabled
22 Remote Start Confirmation Disabled Enabled