Robotis Dynamixel RX-64 Automobile Electronics User Manual


 
18
DYNAMIXEL
RX-64
Goal Speed Setting
Turn Direction = 0 : CCW Direction Turn, Load Direction = 1: CW Direction Turn
Range
Each data has a valid minimum and maximum values. Write instructions made outside
of these valid ranges will return an error. The f ollowing table summarizes th e data range
for each register. 16 bit data registers are indicated with two bytes (L) and (H). Both
bytes need to be written at the same time as one instruction packet.
Write
Address
Writing Item
Length
(bytes)
Min Max
3(0X 0 3) ID 1 0
253(0xfd)
4(0X 0 4) Baud Rate 1 0
254(0xfe)
5(0X05) Return Delay Time 1 0
254(0xfe)
6(0X 0 6) CW Angle Limit 2 0
1023(0x3ff)
8(0X 0 8) CCW Angle Limit 2 0
1023(0x3ff)
11(0X0B) the Highest Limit Temperature 1 0
150(0x9 6)
12(0X0C) the Lowest Limit Voltage 1 50(0x32)
250(0xfa)
13(0X0D) the Highest Limit Voltage 1 50(0 x 3 2)
250(0xfa)
14(0X0E) Max Torque 2 0
1023(0x3ff)
16(0X10) Status Return Level 1 0
2
17(0X11) Alarm LED 1 0
127(0x7f)
18(0X12) Alarm Shutdown 1 0
127(0x7f)
19(0X13) (Reserved) 1 0
1
24(0X18) Torque Enable 1 0
1
25(0X19) LED 1 0
1
26(0X1A) CW Compliance Margin 1 0
254(0xfe)
27(0X1B) CCW Compliance M a rgin 1 0
254(0xfe)
28(0X1C) CW Compliance Slope 1 1
254(0xfe)
29(0X1D) CCW Compliance Slope 1 1
254(0xfe)
30(0X1E) Goal Position 2 0
1023(0x3ff)
32(0X20) Moving Speed 2 0
1023(0x3ff)
34(0X22) Torque Limit 2 0
1023(0x3ff)
44(0X2C) Registered Instruction 1 0
1
47(0X2F) Lock 1 1
1
48(0X30) Punch 2 0
1023(0x3ff)
[Control Table Data Range and Length for Writing]
BIT 15~11 10 9876543210
Value 0 Turn Direction Speed Value