Control Table The Control Table contains information on the status and operation of the Dynamixel
actuator. The Dynamixel actuator is oper ated by writing valu es to its control table and its
status is checked by reading values off its control table.
RAM and EEPROM The data values for the RAM area will be set to the default initial values whenever the
power is turned on. However, the data values for the EEPROM area are non-volatile
and will still remain even after the po wer is turned off.
Initial Value The Initial Value column on the right side of the contr ol tabl e shows the Factory Default
Values for the case of EEPROM area data, and sho ws the initial value when the power
is turned on for the case of RAM area data.
The following explains the meaning of data stored in each of the addresses in the
control table.
Address 0x00,0x01 Model Number
. For RX-64, this value is 0X0040 (64).
Address 0x02 Firmware Version
.
Address 0x03 ID. The unique ID number assigned to each Dynamixel actuators for identifying them.
Different IDs are required for each Dynamixel actuators that are on the s ame network.
Address 0x04 Baud Rate
. Determines the communication speed. The computation is done by the
following formula.
Spee d (BPS) = 2000000 / (Address4 + 1)
Data Value for each Major Baud Rate
Note A maximum Baud Rate error of 3% is within the tolerance of UART communication.
Caution The initial value of Baudrate is set to 34(57600bps)
Adress4 Hex Set BPS Goal BPS Error
1 0X01 1000000.0 1000000.0 0.000%
3 0X03 500000.0 500000.0 0.000%
4 0X04 400000.0 400000.0 0.000%
7 0X07 250000.0 250000.0 0.000%
9 0X09 200000.0 200000.0 0.000%
16 0X10 117647.1 115200.0 -2.124%
34 0X22 57142.9 57600.0 0.794%
103 0X67 19230.8 19200.0 -0.160%
207 0XCF 9615.4 9600.0 -0.160%