Rikaline III GPS Receiver User Manual


 
GPS-6036 Operating Manual
Rikaline
Rikaline International Corp. 14F, 171, Chen-Gong Road, SanChong City, Taipei 241, Taiwan
Tel: ++886 2 8973 1899 Fax: ++886 2 8973 1896 E-Mail: info@rikaline.com.tw
Web: www.rikaline.com.tw
18
Capacity cut-off within 1 hour after complete charge.
3 Cycle Life
Measure the capacity after 300 cycles of complete charge
and discharge at 1C current to 2.75V cut-off
80% of initial Capacity
Capacity after 30days storage at 25 from complete
charge
Retention capacity 90%
4 Storage
Capacity after 7days storage at 60 ffom complete charge Recovery capacity 90%
C.3.2.2 Environmental Characteristic
NO ITEM TESTING INSTRUCTION REQUIREMENTS
1
Temperature
testing
Measure capacity with constant discharge current 1C to 2.75V
cut-off at each temperature after complete charge at 25 .
Percentage as an index of the capacity compared with
100% at 25 .
25% at -20
60% at 0
100% at 25
96% at 60
2
Constant
temperature
/humidity
Keep the battery at 40 and 90%RH for 96hrs Recovery capacity 85%
3 Vibration
The battery will be vibrated 10 times in three mutually
perpendicular directions with amplitude of 0.35mm and
changing frequency between 10 and 55Hz. The rate of
scanning frequency is from 10Hz to 55Hz with the rate of
1Hz per min.
4
Impacting
Testing
The battery will be impacted 1000±10 times with the
acceleration of 100m/s
2
and pulse lasting time 16ms.
5 Free fall
The battery will be dropped free five times in three mutually
perpendicular directions from the height of 1.0m onto a
hard board with the thickness of 20mm
The battery shall not
rupture, smoke, catch fire,
vent or leak.
C.3.2.3 Safe Characteristic
NO ITEM TESTING INSTRUCTION REQUIREMENTS
1 Short Circuit
The battery is to be short-circuited by connecting the
positive and negative terminals of the battery with an
external load of less than 50m
2
Over charge
testing
According to the method of UL
3
Over
discharge
testing
After complete charge, the battery will be discharged to end
voltage. Then Connect with external load of 30 for 24hrs.
The battery shall not
rupture, smoke, catch fire,
vent or leak.
C.3.3 Cautions
1) The best operating performance is between -20 ~ +60 °C. Higher or lower temperature could cause
damage to the battery.
2) Operated with external power supply will not hurt battery life since battery does not discharge. Therefore, it
operating temperature range is -40 ~ +85°C.
3) Recharge the battery for 10 hours before use.