Python 400 ESP Automobile Alarm User Manual


 
© 1999 Directed Electronics, Inc. Vista, CA 7
IMPORTANT! Never use this wire to drive anything but a relay or a low-current input! The transis-
torized output can only provide 200 mA of current, and connecting directly to a solenoid, motor,
or other high-current device will cause it to fail.
Connect this wire to the optional domelight supervision relay as shown below:
IMPORTANT! This output is only intended to drive a relay. It cannot be connected directly to the
domelight circuit, as the output cannot support the current draw of one or more light bulbs.
The H1/6 BLUE output is used for progressive unlock. A progressive unlock system unlocks the driver's door when
the unlock (disarm) button is pressed and unlocks the passenger doors if the unlock (disarm) button is pressed
again within 15 seconds after unlocking the driver's door. The BLUE wire outputs a low current (-) pulse on the
second press of the unlock button of the transmitter. This negative unlock output is used to unlock the passen-
ger doors.
H1/6 BLUE (-) 200 mA second unlock output
H1/4 BLACK/WHITE (-) 200 mA domelight supervision output