164
Specifications
The carburetor jetting chart above is consistent with the provisions of U.S.A. federal regulation 40 CFR 1051.115(d)(3).
OUTLAW 90 Carburetor Jetting
*Shaded cells indicate factory settings.
ALTITUDE
Meters (Feet)
AMBIENT TEMPERATURE
°F: Below -25 -30 to -10 -15 to +5 0 to +20 +15 to +35 +30 to +50 +45 to +65 Above +60
°C: Below-35 -34 to -23 -26 to -15 -18 to -7 -9 to +2 -1 to +10 +7 to +18 Above +16
0-600
(0-2000)
Main Jet 82 82 82 82 80 80 80 80
Pilot Jet 42 42 40 40 40 40 40 40
Clip Position #4 #4 #4 #4 #4 #4 #4 #4
600-1200
(2000-4000)
Main Jet 82 82 82 82
80 80 80 80
Pilot Jet 42 42 40 40 40 40 40 40
Clip Position #4 #4 #4 #4 #4 #4 #4 #4
1200-1800
(4000-6000)
Main Jet 82 82 82 82 80 80 80 80
Pilot Jet 42 42 40 40 40 40 40 40
Clip Position #4 #4 #4 #4 #4 #4 #4 #4
1800-2400
(6000-8000)
Main Jet 82 82 82 82
80 80 80 80
Pilot Jet 42 42 40 40 40 40 40 40
Clip Position #4 #4 #4 #4 #4 #4 #4 #4
2400-3000
(8000-10000)
Main Jet 80 80 808078787878
Pilot Jet 42 42 404040404040
Clip Position #4 #4 #4 #4 #4 #4 #4 #4
3000-3700
(10000-12000)
Main Jet 80 80 808078787878
Pilot Jet 42 42 404040404040
Clip Position #4 #4 #4 #4 #4 #4 #4 #4