16
WARNING SYSTEM
Warning Display Screens
12
10
9
11
13
14
16
no starboard
engine
15
0
1
2
3
4
5
6
7
Multiple
Starboard Engine
9. FAULT-IGNITION – A problem has developed in the ignition sys-
tem.
10. BATTERY – The electrical system is not charging or the battery
charge is low.
11. ENGINE DATA BUS – The data communication link between the
tachometer and engine is not connected.
12. FAULT-SENSOR – One of the sensors is not functioning correctly.
13. FAULT-WATER TEMP – The sensor for measuring outside lake/
sea water temperature is not functioning correctly.
14. NO STARBOARD ENGINE – Informs you that the Instrument
does not see the starboard engine computer. Usually indicates
that no data is being transferred from the engine’s computer to the
gauge. (Check wiring, also make sure both terminator resistors are
installed in the bus). Make sure both ECMs are not configured for
port location using a DDT or Quicksilver Diagnostic Tool.
15. MULTIPLE STARBOARD ENGINE – SmartCraft Gauges are
recognizing multiple engines as starboard.
In multiple engine applications, each engine must first be assigned a
position (starboard, port, starboard2 or port2) with a Quicksilver Diag-
nostic Tool before the system will function properly.
If you have a dual engine application, you must first program the port
engine with a Quicksilver Diagnostic Tool.
16. OIL TEMPERATURE – Engine oil is overheating.