TACHOMETER CALIBRATION
27
1. Press and hold the "MODE/SELECT" and "+" buttons for
approximately seven seconds until the "CAL 1" screen
appears.
2. Press the "-" or "+" button to select the option choice displayed
in the [ ] brackets on the screen.
3. Press "MODE/SELECT" ["SAVE"] to save the setting and
advance through the calibration screens.
Tachometer CAL 1 Calibration - Remote Light and Contrast
[SAVE] [ YES ]
23620
REMOTE SCREENS ?
[ NO ]
If "YES" is selected, then screen changes made
on this tachometer will effect all tachometers in
the system. All tachometers need the screen set
to "YES" for this function to work.
[ NO ]
[SAVE] [YES ]
23532
REMOTE LCD LIGHT ?
Adjusts the lighting levels on all gauges
simultaneously from this gauge. If "YES" is
selected, then lighting levels changes made on
this tachometer will effect all tachometers in the
system. All tachometers need the screen set to
"YES" for this function to work.
[ NO ]
[SAVE] [YES ]
23533
REMOTE LCD CONTRAST ?
Adjusts the contrast of another System/Smart
Tow Tachometer simultaneously from this
gauge. If "YES" is selected, then contrast level
changes made on this tachometer will effect all
tachometers in the system. All tachometers
need the screen set to "YES" for this function to
work.
Tachometer CAL 1 Calibration - Trim
[SAVE] [ YES ]
23621
HIGH RESOLUTION TRIM ?
[ NO ]
Enables the trim angle to be displayed in 0.1°
increments if "YES" is selected.
[SAVE] [ YES ]
23641
TRIM POPUP ?
[ NO ]
The trim display screen pops up when the trim
setting is changed if "YES" is selected.
TRIM CALIBRATION
CALIBRATION 1
[SKIP] [EDIT]
23910
Select "EDIT" to calibrate the gauge to the
standard 0 - 10° unit trim and 11 - 25° trailer
position scale. Select "SKIP" to advance to the
next selection.