4.9 COMMUNICATOR 4 BY 2 FORMAT
NOTE: Section 4.9 pertains to the 4 by 2 communicator format only.
PURPOSE:
For configuring how the 4 by 2 format will report to the central station.
General reporting or Point-to-Point reporting methods are available for
the 4 by 2 format.
GENERAL REPORTING
General reporting can send three report codes for sensors: FIRE,
EMERGENCY, and TROUBLE. General reporting does not indicate
which sensor caused the report.
POINT-TO-POINT REPORTING
Point-to-Point reporting can send 40 report codes. Each sensor/zone has
a unique ALARM code and TROUBLE code.
NOTE: With either reporting method, the Console report codes are
the same (see Section 4.9.3).
USER RESPONSE:
4 BY 2 FORMAT
Select POINT-TO-POINT to have the Console’s communicator
send 4 by 2 Point-to-Point report codes.
Select GENERAL to have the Console’s communicator send only
the three General 4 by 2 report codes.