Linear RA-2400 Remote Starter User Manual


 
Black 0023
Black0023
4.5 SENSORS (CONTINUED)
SENSOR
OPTIONS
SENSOR
STATUS
DELAYED ALARM SETTING
Click on the sensor in the menu tree to
view it.
View or edit the DELAYED ALARM
SETTING.
The delayed alarm settings are:
DISABLED
An alarm transmission received on specified
zones will not be delayed.
15 MINUTE DELAY
An alarm transmission received on specified
zones will be delayed for 15 minutes.
30 MINUTE DELAY
An alarm transmission received on specified
zones will be delayed for 30 minutes.
NOTE: If a transmitter restore is received
prior to the timeout period, then the alarm
will be automatically cancelled and the unit
will return to normal standby operation.
This function is ignored for Fire and Activity
Reset sensors.
SENSOR OPTIONS
View or edit the SENSOR OPTIONS.
These options are automatically set when
the sensor is programmed into the
Console.
The sensor options are:
AUTO RESTORE
This box should be checked for all model sensors
except the Model DXS-31.
SUPERVISED
This box should be checked for all sensors that
send periodic status reports. DXT sensors do not
send periodic status reports. REMOVE THE
CHECK FROM THIS BOX IF A MODEL DXT
SENSOR HAS BEEN PROGRAMMED INTO THIS
SENSOR LOCATION or if you don’t want
supervision for that sensor. This will keep the
Console TROUBLE indicator from lighting due to
missing status reports.
NOTE: The sensor can still report a low
battery condition (see Section 4.8) this will
cause the Console’s TROUBLE indicator
to flash.
SILENT ALARM
This box should be checked for all sensors that
need to be silent locally. Fire or Activity Reset
sensors will not be silent.
TWO-WAY VOICE ACTIVATION
This box should be checked for all sensors that
require two-way voice activation. Checking this
box will not enable Two-way audio if NONE is
selected in the CONSOLE AUDIO screen.
SENSOR STATUS
View the SENSOR STATUS to see the
condition of the sensor selected.
The sensor status conditions are:
LOW BATTERY
The sensor has sent a low battery signal to the
Console. Replace the sensor’s battery.
TROUBLE
The Console has not received a status report from
this sensor in 24 hours. Sensor may have been
out of range of the Console’s receiver, or the
sensor may be non-functional.
NOTE: After any changes are made to the
sensor type or sensor options, test the
sensor to verify proper operation.
INSTR,RA-2400/PERS-2400,REF GUIDE
LINEAR P/N: 217163 E
INK: BLACK
MATERIAL: 20 LB. MEAD BOND
SIZE: 8.500" X 5.500"
SCALE: 1-1
21