4.6 COMMUNICATOR MAIN
PURPOSE:
For configuring the Console’s communicator format, dialing method,
remote access password, dialing delay, and auto answer options.
USER RESPONSE:
COMMUNICATOR MAIN
✦ Check the ON box to enable the communicator in the Console.
☞ NOTE: You may want to turn the communicator off while testing the
system to prevent the Console from trying to dial out when it is not
connected to a telephone line.
FORMAT
✦ Select between 4 BY 2 and ADEMCO CONTACT ID for the
communicator format depending on the Central Station’s requirements.
DIAL METHOD
✦ Select TONE or PULSE dialing for the Console.
REMOTE ACCESS PASSWORD
✦ Enter a six-digit password. This is the password required to
connect to the Console with the RA-2400 program. The default
password is “987654". DO NOT FORGET THIS PASSWORD,
LOCAL OR REMOTE PROGRAMMING ACCESS TO THE
PERS-2400 IS IMPOSSIBLE WITHOUT IT.
15 SECOND DIALING DELAY
✦ Check this box if you want a 15 second delay before the
communicator starts to dial after an alarm. This gives the
subscriber time to cancel an alarm and central station report by
pressing the Console’s CLEAR button before the unit dials out.
PREVENT CONSOLE FROM ANSWERING THE PHONE
✦ Check this box to disable the Console’s telephone ring detection
feature. This keeps the Console from automatically answering the
phone. Even if this box is checked, the Console can still be
programmed by placing the Console into Test Mode and forcing
the Console to answer by pressing the EMERGENCY button while
the phone is ringing.