KTM KTM250 SX Automobile Parts User Manual


 
Ignition (Kokusan)
General information
The measurements described below will only reveal severe problems. Coil
short circuits leading to weak ignition sparks or low generator output,
respectively, can only be detected with the help of an ignition test bench.
In the case of malfunction always check the cables and the plug and
socket connections of the ignition system first.
Make sure to select the correct measuring range when performing
measurements.
Spark plug
Set the electrode distance.
Electrode distance: 0.60 mm (0.024 in)
Insulator
Check for cracks and fissures.
!
CAUTION
!
A
LWAYS USE A SPARK PLUG WITH RESISTOR. OTHERWISE PROBLEMS CAN OCCUR IN
THE
CDI UNIT.
Check stator and pulse generator (Kokusan)
Use an ohmmeter to perform the following measurements:
NOTE: The measuring must be performed at a temperature of 20° C.
Otherwise significant deviations must be expected.
Replace the stator if the measured values deviate significantly from the
setpoint values.
2K-1
2K-2
2K-3
2K-4
5-13C
Ignition Measure Cable colours Resistance
2K-1 Pulser coil red – green 100 ע15%
Exciter
black/red – red/white
24 ע15%
2K-2 Pulser coil red – green 100 ע15%
Exciter
black/red – red/white
24 ע15%
Charge coil ground – yellow 0,74 ע15%
2K-3 Pulser coil red – green 100 ע15%
Exciter
black/red – red/white
12.7 ע15%
Charge coil ground – yellow 0.65 ע15%
white – yellow 0.16 ע15%
2K-4 Pulser coil red – green 100 ע15%
Exciter
black/red – red/white
24 ע15%
Charge coil yellow – yellow 0.65 ע15%
Kokusan 2K-1/2K-4
Kokusan 2K-2
Kokusan 2K-3