Graco 205395 Series N Automobile Parts User Manual


 
Installation
306674V 5
Be sure the air hose is properly sized to deliver an ade-
quate supply of air to the motor. Refer to the Technical
Data on page 16.
Connect a dispensing hose to the 3/8 npt(f) pump outlet.
Install an appropriate gun or dispense valve to the hose.
Ground the pump as explained on page 4.
Key:
A Grounded air line
B Bleed-type master air valve
CAir filter
D Air line oiler
E Air regulator
F Grounded dispensing hose
G Dispensing valve
H Elevator assembly with inductors
J Ground wire
A bleed-type master air valve (B) is required to shut
off an relieve air pressure that may be trapped in the
air motor. Trapped air could cause the pump to cycle
unexpectedly and cause serious bodily injury,
including amputation.
FIG. 2: Typical Installation
A
B
CD
E
H
J
F
G