Garmin GDU 375 GPS Receiver User Manual


 
GDU 37X Installation Manual – Appendix B Page B-11
190-01054-01 Revision B
B.1.6. Daisy Chain between Methods A and B
In rare situations where more braids need to be terminated for a connector than three per ring terminal and
a mixture of Methods A and B have been used, it is allowable to daisy chain a maximum of two shields
together from a Method A termination to a Method B (Figure B-7). All other restrictions and instructions
for the shield termination technique set forth for Method A and B are still applicable.
NOTE
The maximum length of the combined braids should be approximately
4 inches.
Figure B-7. Daisy Chain between Methods A and B