6. INITIAL SETTINGS
20
Setting DATA 4 to Data Output
1) Press MENU ESC, 9 and 5. The DATA 4 I/O SETUP menu appears.
DATA 4 I/O SETUP 1/2
To Next Page
ENT : Enter MENU : Escape
Appears only when external
DGPS receiver is used.
DATA 4. Level RS232C RS422
Data Out Com. DGPS
: Select
DATA 4 I/O SETUP menu
2) Press
S or T to select DATA4. Level.
3) Press
W or X to select level of external equipment; RS232C or RS422.
4) Press the NU/CU ENT key.
5) Press
W or X to select Out.
6) Press
T to select to Next Page. The DATA 4 I/O SETUP <out> menu appears.
To Previous Page
Talker ID GP LC DE
Output Data (00-90 sec) 100%
DATA 4 I/O SETUP <Out> 2/2
MENU : Escape
ENT : Enter
Data Fmt. V1.5 V2.0 IEC
1. AAM:00 APA:00 APB:04 BOD:00
2. BWR:00 BWW:00 GGA:00 GLL:01
3. RMB:01 RMC:00 VTG:01 WCV:00
4. VDR:00 WPL:00 XTE:00 ZDA:01
5. GNS:00 GBS:01 Rnn:00 RTE:00
DATA 4 I/O SETUP <out> menu
7) Follow "DATA 1 output setting" from step 2.