Furuno GP-150 GPS Receiver User Manual


 
6. INITIAL SETTINGS
19
DATA 2 output setting
1) Press NU/CU MENU, 9 and 4. The DATA 2 OUTPUT SETUP menu appears.
Talker ID GP LC DE
Output Data (00-90 sec) 100%
DATA2 OUTPUT SETUP
MENU : Escape
ENT : Enter
Data Fmt.
V1.5
: Select
Setting shown here are default settings.
1. AAM:00 APA:00 APB:04 BOD:00
2. BWR:00 BWW:00 GGA:00 GLL:01
3. RMB:01 RMC:00 VTG:01 WCV:00
4. VDR:00 WPL:00 XTE:00 ZDA:01
5. GNS:00 GBS:01 Rnn:00 RTE:00
V2.0
IEC
DATA 2 OUTPUT SETUP menu
2) Follow the procedure for setting DATA 1 output.
DATA 3 output setting
The DATA 3 can output NMEA 0183 (V1.5/V2.0) /IEC 61162-1 data or log pulse by
selecting inner jumper blocks. For NMEA 0183 (V1.5/V2.0) /IEC 61162-1, the same signal
of DATA 1 is output from DATA 3.
Selection of NMEA0183 or log pulse
Output data
NP board
NMEA 0183 (V1.5/
V2.0)/IEC 61162-1
(default setting)
Log pulse
JP3 #1-2 #2-3
JP4 #1-2 #2-3
JP10 #1-2 #2-3
Rate of log pulse output
150 mA Max.
50 VDC
Procedure for setting of log pulse rate
1) Press MENU ESC, 9 and 3.
2) Press
S or T to select “DATA 3. Log Pulse”.
3) Press
W or X to select log pulse for external equipment; 200 ppm or 400 ppm.
4) Press the NU/CU ENT key.
5) Press the MENU ESC key.