2. MAINTENANCE, TROUBLESHOOTING
19
2.2 Replacing the Fuse
The fuse (5 A) in the power cable protects the equipment against reverse polarity of the ship’s
mains, overcurrent, and equipment fault. If the fuse blows, find the cause before replacing it.
Use the proper fuse.
Use of a wrong fuse may cause
serious damage to the equipment
and void the warranty.
CAUTION
2.3 Troubleshooting
The table below provides simple troubleshooting procedures which the user can follow to
restore normal operation. If you cannot restore normal operation contact your dealer for advice.
Troubleshooting
If… But… Then…
nothing appears on the display
or display contrast is poor
try adjusting LCD contrast.
battery may have
discharged; check battery.
check if fuse has blown.
you pressed the
[POWER/BRILL] key to turn on
the radar
the control panel does not light adjust PANEL DIMMER on the
User menu.
the message “NO HEADING
PULSE” or “NO BEARING
PULSE” appears
check that the antenna cable is
firmly connected.
the radar has warmed up and
you pressed the [MODE] key
to transmit
neither noise or targets appear
(characters and markers do)
try adjusting gain, A/C SEA
and A/C RAIN.
check antenna cable for
damage.
a key is pressed nothing happens key may be faulty. Contact
your dealer.
the display freezes press the [POWER/BRILL] key
about five seconds to turn off
the power and then turn it on
again.