1035/El-O-Matic Actuator
Instruction Manual
Form 5417
February 2007
3
Table 2. Performance Characteristics
E SERIES
ACTUATOR
BORE STROKE
AVERAGE
STROKE
FREE AIR VOLUME
(2)
FREE AIR
VOLUME
(2)
ACTUATOR
SIZE
mm Inch mm Inch
STROKE
TIME
(SEC)
(1)
Port
‘‘A’’(liter)
Port
‘‘A’’(in
3
)
Port
‘‘B’’(liter)
Port
‘‘B’’(in
3
)
E25 56 2.2 15.7 0.62 0.5 0.1 6.1 0.11 6.7
E40 70 2.8 18.8 0.74 0.7 0.16 9.8 0.22 13.4
E85 80 3.1 22.0 0.87 1.1 0.33 20.1 0.36 22.0
E100 91 3.6 25.1 0.99 1.2 0.35 21.4 0.49 29.9
E200 110 4.3 37.7 1.48 2.2 0.8 48.8 1.0 61.0
E350 145 5.7 37.7 1.48 3.7 1.8 110 1.9 116
E600 175 6.9 44.0 1.73 3.3 2.9 177 3.1 189
E950 200 7.9 50.3 1.98 5.4 4.7 287 4.9 299
E1600 230 9.1 62.8 2.47 5.8 7.3 445 8.0 488
P2500/P2505 300 11.8 56.5 2.22 6.7 8.0 488 9.3 567
P4000/P4005 325 12.8 81.7 3.22 12.4 13.5 824 17.5 1068
1. These times assume smaller solenoids for smaller actuators and larger solenoids for larger actuators with varying Cvs, but a constant air supply pressure of 80 psi (5.51 bar). E25 to
E350 assume a 0.09 Cv (0.08 Kv); E600 & E9500 a 0.26 Cv (0.22 Kv); E1600, P2505 & P4005 a 0.51 Cv (0.44 Kv).
2. To calculate air consumption per stroke multiply free air volume X air supply pressure (absolute).
Figure 2. Typical Actuator Assembly
SPRING
STANDARD SQUARE END
STANDARD SQUAREDOUBLE D CONNECTION
COUPLER
DOUBLE ACTING
ACTUATOR
E SERIES INSERT
END CAP SPRING RETURN
W6954 / IL