Directed Electronics 5 Automobile Alarm User Manual


 
23
© 2004 directed electronics, inc.
auto arm - on/off
z
On: When the system sees the ignition turn off and the last
protected entry (door, hood, or trunk) close, it will begin a
30-second countdown before arming itself. After the first
five seconds, you will hear two chirps and the lights will
flash. The system will arm 25 seconds later.
z
Off: The transmitter must be used to arm the system.
chirps - on/off/quiet
z
On: Chirps will sound when arming/disarming the system.
z
Off: Chirps will not sound when arming/disarming the system.
z
Quiet: Chirps will sound when arming/disarming the system
but at a lower pitch tone than normal. This feature is only
available with the 515C siren.
auto lock - ignition/off/rpm
z
Ignition: The doors will automatically lock three seconds
after the ignition is turned on unless a door is open at that
time.
z
Off: The doors will not lock automatically.
z
Rpm: The doors will lock when the system sees the engine
reach a preprogrammed RPM. This feature is only available
with IntelliStart.
auto unlock - ignition/off
z
Ignition: The doors will automatically unlock as soon as the
ignition is turned off.
z
Off: The doors will not automatically unlock when the igni-
tion is turned off.