Directed Electronics 5 Automobile Alarm User Manual


 
14
Doors are covered by FACT II differently; if the alarm is triggered by an
open door for three full cycles, the doors will be bypassed until the trig-
ger ceases. FACT II is programmable. See the Programming Options
section of this guide.
select siren sounds
Selectable siren sounds are available with the optional self-powered
smart siren (515C) only. Contact your local dealer for more information.
The 515C transmits a two-way digital signal between itself and the con-
trol unit. If a thief disconnects power and/or cuts or tampers with any or
all of the siren wires while the system is armed, the siren will sound for
five minutes and then reset. Since this will only occur while the system is
armed, there is no need for a siren override key. Unlike other back-up
battery sirens that constantly drain the car battery, Clifford’s design draws
charging current only when the ignition is on (i.e., engine running). If the
internal battery is discharged, the arm/disarm chirps are muted.
If a self-powered smart siren has been added to your system, please
refer to the selectable siren sounds feature in the User Selectable
Features grid. Once in programming mode, press on the trans-
mitter to begin playback of the available sounds.
nnoottee::
Arming and disarming the system does not reset this function! The
only way to reset a bypassed zone is for 60 minutes or to turn on the
ignition. If testing your system, it is important to remember that the FACT
II programming can cause zones to be bypassed and appear to stop
working. If you wish to clear the FACT II memory, turn the ignition key
on.