Crimestopper Security Products CS-8050 Automobile Alarm User Manual


 
WIRING
WIRE #5: +12Volt Power Input:
Connect to Battery Positive Terminal.
WIRE #6: Immobilizer Circuit #1 Output:
This is part of the immobilizer circuit (on-board relay). Cut the Ignition wire and connect ONE end to this wire.
WIRE #7: Immobilizer #1 Input:
This is part of the immobilizer circuit (on-board relay). Connect the other end of the Ignition wire to this wire.
WIRE #8: (-) Horn Honk Output (Optional, may require relay):
Connects to (-) Negative Horn activation circuit on vehicle to honk vehicle’s horn when the system is triggered.
If the vehicle has a +12V positive horn circuit, then a relay is required. Connect to terminal 85 of a relay.
Connect terminals 86 & 87 to +12V Constant Power. Connect terminal 30 to the Positive horn activation
circuit.
WIRE #9: (-) Neg. Dome Light Illumination or Factory Disarm Output (Optional, requires relay):
This output can be programmed to turn on the Domelight for 30 seconds upon disarming for illuminated entry
at night, or to be a .5 Second negative disarm pulse for Factory Alarm system. When used a Domelight
output, a relay is required: Connect the #9 wire to terminal 85 of a relay. Connect terminal 86 to +12V
Constant. Connect terminal 87 to +12V or Ground depending on the type of dome light circuit in the vehicle.
Connect terminal 30 to the dome light circuit.
WIRE #10: (-) Negative Armed Output (Optional):
Provide (-) 500mA output when armed. This wire can be used to add an additional Immobilizer Circuit or other
accessory such as scanner type LEDs or window roll up modules (not included).
MINI PLUGS: LED / VALET-PROGRAMMING SWITCH / DOOR LOCKS
Mount the LED in a visible location, then connect 2-pin Red plug to the Red Connector on the module
Mount the Override/Valet button and connect 2-pin Blue plug to the Blue connector on the module.
Blue Wire: (-) Negative Door Unlock Output
Red Wire (+) +12Volts Constant Output: Connect to terminal 86 (relay coil power) of Aftermarket relay for
activating positive, reverse polarity, and after market door locking systems.
Green Wire: (-) Negative Door Lock Output