Blizzard Entertainment 810SS Automobile Accessories User Manual


 
TROUBLESHOOTING
22
64060 (2005-810&8611SkidSteer).doc
PROBLEM CAUSE SOLUTION
S5 coil is not magnetizing.
S5 coil should magnetize with each
function.
Plow functions will not work after all
connections are made or plow functions
are slow.
Solenoid cartridge valve may be
contaminated or damaged. A bent or
over torqued cartridge will not allow the
valve to move freely inside of the
cartridge.
Determine a damaged cartridge valve
by reversing the driver’s side and
passenger’s side cartridge valves one at
a time. Replace valve if necessary.
Plow functions start and terminate
suddenly.
Skid steer hydraulic fluid flow is set to
variable flow.
For plow functions to work, the skid
steer hydraulic fluid flow should be set
to continuous flow. Review your skid
steer operation manual for proper flow
settings.
Diodes may be corroded or damaged. Clean diodes thoroughly and/or replace.
Multiple valves function simultaneously.
Wire harness may be damaged.
Verify harness is not damaged. Review
schematic(s) to troubleshoot
connection(s). Replace if needed.
Plow functions are reversed (i.e.
Driver’s side wing extends when
passenger’s side wing is activated from
the control.)
Hydraulic hoses are connected wrong
or coils and wiring are incorrect.
Review the Hydraulic Valve &Hose Port
Identification Guide under the A-frame
cover for proper port locations and/or
place respective coils over correct
valves.
Both wings extend when the skid steer
hydraulics are turned on.
Pressure (P) and tank (T) hoses are
installed in the wrong position on the
skid steer.
Review the skid steer operation manual
to determine the pressure and tank
connections.
Plow angles only one way.
Skid steer computer conflicts with
cylindrical connection.
Using a jumper wire, connect pin K to
pin L at the back of the cylindrical
connector (cylindrical connector only).
Wing will not stay angled when plowing.
The wing pressure relief valve is
contaminated.
Test the wing pressure relief. Attach a
T-fitting with a fluid PSI gauge to the
base end of the wing cylinder. Pressure
relief should not be greater than
1700PSI (2800PSI for 8611SS) Replace
if less than 1500-1700PSI (2600-
2800PSI).
Plow will not stay angled when plowing.
The angle pressure relief valve is set
too low. NOTE: Increasing the pressure
relief valve will cause damage to your
plow. Do not set the pressure relief
greater than 3000PSI.
Follow the guidelines indicated above;
however, the PSI setting should not
exceed 3000PSI. NOTE: If the plow is
floating back when angled to the right,
adjust the left pressure relief valve and
vice versa.
Control station, harness or cables may
be loose or improperly connected.
Verify control station, harness and all
cables are securely connected. Clean if
necessary.
Wing will not move.
No power to the cartridge valve.
Verify S9 &S10 coils (passenger’s side
slide box retract and extend) and S1
&S2 (driver’s side slide box retract and
extend) are connected properly.
Diagnose the wire harness. Review all
wire harness schematics. If power is
present, review the next step.
Wing will not move. Coils are receiving power.
Verify coils are magnetizing. Position a
screwdriver inside of the coil. When the
respective function is activated, the
screwdriver is drawn to the side of the
coil. If the coil is not drawn to the
screwdriver, replace the coil. If power is
present, review the next step.
Solenoid cartridge may be
contaminated or damaged. A bent
cartridge will not allow the valve to
move freely inside of the cartridge.
Determine a damaged cartridge valve
by reversing the driver’s side and
passenger’s side cartridge valves.
Replace valve if necessary.
Plow will not angle. Review all probable causes above.
NOTE: Verify coils S3 & S4 for angle
functions.
Should your snowplow develop other problems not indicated, contact your local Dealer for technical assistance and/or
replacement parts.