Antari Lighting and Effects W-515 Automobile Accessories User Manual


 
If channel A has a value from 0 to 5, the unit is off.
Between the values 6 to 255 the fog output volume is regulated. With
6 being the minimum output volume and 255 approaching the
maximum output volume. The output volume rises as the DMX value is
increased.
Note: If, for example, the machine is assigned to the DMX address 124,
channel A corresponds to DMX address 124.
Note
If you experience low output, pump noise or no output at all, unplug
immediately. Check the fluid level, the external fuse, the connection to the
remote control, and power from the wall. If all of the above appears to be
O.K., plug the unit again. If fog does not come out after holding the remote
button down for 30 seconds, check the hose attached to the tank to make
sure there is fluid going through the hose. If you are unable to determine the
cause of the problem, do not simply continue pushing the remote button, as
this may damage the unit. Return the machine to your Antari dealer.
W-515 External View
01-Nozzle
02-Handle
03-Body
04-Tank & tank’s cap
05-PU tube & filter
06-Tube adaptor
07-Safety ring
08-Control outlet socket
(3 Pin XLR for DMX)
09-Control inlet socker
(3 Pin XLR for DMX)
10-Control outlet socket
(5 Pin XLR for DMX)
11-Control inlet socket
(5 Pin XLR for DMX)
12-Rocker switch / Power
13-Circuit breaker
14-Power socket
15-W-1 wireless receiver
16-Control panel
17-Foot
18-Power cord
19-W-1 wireless transmitter
04
05
03
02
01
06
07
17
-08-