Unit 4: Operation
SATO M5900RVe Operator Manual PN 9001125A Page 4-21
REPRINT W/FEED
YES NO
Sets reprint of previous labels. Prints one page of the previously
printed contents by pressing the FEED key during ONLINE. The
default value is NO: do not reprint. LINE key moves the cursor
and the FEED key selects the option.
FORWARD/BACKFEED
DISTANCE DEFAULT
Sets the peel-off paper feed distance. The paper feed/backfeed
may be set from 0-255mm. The actual Feed/Backfeed distance
is equivalent to VR value + Paper Feed quantity. LINE key
moves the cursor and the FEED key selects the option.
EXT PIN9 SELECT
MODE1 MODE2
Switches to external signal (9 pins) output mode. LINE key
moves the cursor and the FEED key selects the option.
EURO CODE Sets Euro Code. Selects the assigned code of the Euro mark.
The default value is D5 (HEX). LINE key moves the cursor and
the FEED key selects the option.
SELECT LANGUAGE Sets the language to be displayed on the LCD screen. There
are eight language options available. LINE key moves the
cursor and the FEED key selects the option.
PRIORITY SETTING
COMMAND LCD
Sets priority of commands. Sets software commands as being
invalid in regards to print darkness, print speed, and base
reference point id LCD is selected. The default value is
COMMAND: conned settings are valid. LINE key moves the
cursor and the FEED key selects the option.
IGNORE CAN/DLE
YES NO
Sets 1 byte command as being valid or invalid. Displays only
when status 4 is selected. A NO value equals: Invalid.
IEEE1284
ACK SIGNAL 00.5
Sets to ACK signal width of the IEEE1284. Displays only when
the IEEE1284 board is installed. The default value is 0.5.
COUNTERS MODE
MENU DESCRIPTION
COUNTERS
HD DSP CUT LIFE
Selects the counter category: Print head, Dispenser, Cutter, Life
Cycle. LINE key moves the cursor and the FEED key selects
the option.
HEAD COUNTER
0.0M
Print Head counter display. Displays the quantity of times the
print head has cycled.
HEAD COUNT CLEAR
YES NO
Offers the option to reset the counter to zero. The default value
is NO. LINE key moves the cursor and the FEED key selects
the option.
DSP COUNTER
0.0M
Dispenser counter display. Displays the quantity of times the
dispenser has cycled.
DSP COUNT CLEAR
YES NO
Offers the option to reset the counter to zero. The default value
is NO. LINE key moves the cursor and the FEED key selects
the option.
CUT COUNTER
0.0M
Cutter counter display. Displays the quantity of times the cutter
has cycled.
SERVICE MODE