DSW2 DEFAULT SETTINGS
2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8
OFFOFFOFFOFFOFFOFFOFFOFF
DSW2 CONFIGURATION
DSW1 FUNCTION SETTING CONFIGURATION
2-1 Reserved
OFF
ON
2-2 Media Sensor Selection
OFF Gap Sensor
ON Eye-Mark Sensor
2-3 Head Check
OFF Head Check Disabled
ON Head Check Enabled
2-4 Hex Dump
OFF Hex Dump Disabled.
ON Hex Dump Enabled
2-5 Multi-Job Receive Buffer
OFF Single Job Receive Buffer
ON Multi-Job Receive Buffer
2-6 Firmware Download
OFF Disabled
ON Enabled
2-7 Protocol Code
OFF Standard Protocol Mode
ON Non-Standard Protocol Mode
2-8 Operational Mode
OFF Normal Operation
ON Emulation Mode for Original M5900
DSW2 FUNCTION DESCRIPTIONS
FUNCTION DESCRIPTION
Media Sensor Selection Selects between a Gap or Eye-Mark detector.
Head Check When enabled, will check for malfunctioning head elements.
Hex Dump Allows hexadecimal printing of all data received to the print buffer.
Multi-Job Receive Buffer
Allows to continuously receive print jobs while compiling and printing
other jobs.
Firmware Download Places printer in mode for downloading software into flash ROM.
Protocol Code Selects the command codes used for protocol control.