A SERVICE OF

logo

17
SWING GATE OPERATOR
21-1/2"
APPROX.
16"
24" MIN.
ELECTRICAL CONDUIT
PER LOCAL CODE
TOP MOUNTING ANGLE
2" U-BOLTS
2" O.D. (MOUNTING POST)
BY OTHERS
LOWER
MOUNTING
PLATE
4" MIN.
Figure 5
OPERATOR INSTALLATION
1. Mount operator on posts with mounting angles, and
mounting plates. Secure position with 2” U-bolts, and
hardware provided. See figure #5.
2. Set control arm on output shaft of operator without drive
key, and install control arm extension using hand knobs
to secure position. See figure #6.
3/8" BOLT
3/8" LOCK WASHER
3/8" WASHER
1/4" DRIVE KEY
CONTROL ARM
OPERATOR
DRIVE SHAFT
CONTROL ARM
EXTENSION
HAND KNOBS FOR MANUAL DISCONNECT
(USE HOLES SHOWN AS STARTING
POSITION FOR INITIAL SETUP)
Figure 6
NOTE:
TO DISCONNECT OPERATOR FOR
MANUAL OPERATION; REMOVE
HAND KNOBS AND SEPARATE
CONTROL ARM EXTENSION FROM
CONTROL ARM.
MOUNTING
ANGLE
MOUNTING
PLATE
OPERATOR
18
3. Install end fittings on connecting rod assembly and
attach one end of assembly to end of control arm
extension. See figure #7.
Figure 7
3/8" PIVOT BOLT
FLAT WASHER
FLAT WASHER
SPACER BUSHING
LOCK WASHER
3/8" HEX NUT
GATE BRACKET
GATE ARM
SET SCREWS
3/8" PIVOT BOLT
FLAT WASHER
SPACER BUSHING
LOCK WASHER
3/8" HEX NUT
TUBE SPACER
END FITTING
SAFTEY
DISC
FLAT WASHER
SET SCREWS
END FITTING
FLAT WASHER
SPLICE BAR
CONNECTING
ROD (2 PCS.)
ROLL
PIN (4)
4. Install gate bracket on remaining end of connecting rod
(See figures #7 & #8.
5. Locate gate bracket in position on gate, as shown in
figure #8, and clamp in position.
6. Move control arm to its maximum close position. See
figure #8. Control arm and connecting rod must be
straight in line.
Figure 8
GATE HINGE
CONNECTING ROD ASSEMBLY
CONTROL ARM
ELECTRICAL
ACCESS
OPERATOR
CONTROL ARM
PIVOT BOLT
GATE BRACKET
PIVOT BOLT
GATE BRACKET
GATE ANGLE
(BY OTHERS)
OF GATE
C
L
36"
SAFETY DISC