29
ACCESORY CONTROL CONNECTIONS
RADIO CONTROL INSTALLATION
A Three or Four wire radio control receiver can be
installed on this operator. This radio control receiver can
only be used to open the gate, therefore the “TIMER TO
CLOSE” option must be activated for closing.
NOTE: If your radio’s connecting wires are not color
coded as shown, see the radio’s installation manual to
determine which wires are for the normally open
contacts and which require the 24 VAC Power Supply.
4 WIRE
RADIO
R1
R2
R3
GY
R
BK
GY
R4
N.O.
CONTACT
RADIO CONTROL
TERMINAL
Figure 13
24 VAC
USE THESE
3 TERMINALS
FOR 3-WIRE
RADIO CONTROL
30
LOOP DETECTOR SYSTEMS AND INSTALLATION
The diagram below depicts the typical loop options for a
Slide Gate installation.
1. The Exit Loop provides a signal to open the gate
when a vehicle enters the loop zone.
2. The Reversing Loop protects a vehicle in the loop
zone from being contacted with the gate by over-
riding any close signal while the gate is open, and
by reversing the gate if closing.
3. The Shadow Loop protects a vehicle in the loop
zone from being contacted with the gate by
overriding any close signal while the gate is in the
full open position.
4'
4'
4'
4'
4'
Road Surface
Sealant
Loop wires
Min 1"
3/16" To 1/4"
Saw Slot
4'
4'
Approx.
10'