![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/29/c291777c-8dda-47b2-b822-65df3a80514b/c291777c-8dda-47b2-b822-65df3a80514b-bg14.png)
39
3. Connect NON-CONTACT sensors to the control board
as shown below.
NON CONTACT SENSOR CONNECTION
Close Photocell
Sensor
Open Photocell
Sensor
Align With
Reflector
Align With
Reflector
10 11 12 13 14
Reflector Reflector
NOTE: Close photocell is connected to terminal #11 and
terminal #14. Open photocell is connected to terminal #10
and terminal #14.
AFTER SENSORS ARE CONNECTED:
1. Turn on power.
2. Make sure the photo-beams are properly aligned per
the manufacturer’s specifications.
3. Test the CLOSE obstruction sensing system for proper
operation, by blocking the beam across the gate
opening while the gate is running closed.
NOTE: The gate should stop and reverse a short distance
and then stop.
4. Run operator to close limit.
5. Test the OPEN obstruction sensing system by
blocking the beam mounted at the back area of the
gate while the gate is running open.
NOTE:
The operator should repeat the stop and reverse
procedure.
40
PowerMaster
Limited 5 Year Warranty
PowerMaster warrants all gate operators to be free of defects in
materials and workmanship for a period of Five (5) years from date
of purchase. If any part is found to be defective during this period,
new parts will be furnished free of charge. Failure of this product
due to misuse, improper installation, alterations, vandalism, or lack
of maintenance is not covered under this warranty, and voids any
other implied warranties herein.
PowerMaster is not responsible for any labor charges incurred in
connection with the installation of warranted parts.
In order to activate this warranty, the registration form on
opposite page MUST be completed and returned within
THIRTY CALENDER DAYS FROM DATE OF PURCHASE
VIA CERTIFIED MAIL, fax (631-951-3934) or via email
techsupport@power-master.net If registration is not
activated, a one year warranty will apply.
The end user should
retain this information
for their records and to
in
rr
n
r
i
Model MSW
Date Installed____________
Serial # ________________
Installer’s Information
Company Name _____________________
Company Address ___________________
Company Address ___________________
Company Address ___________________
Company Telephone # ________________
Company Contact ____________________
The end user should
retain this information
for their records and to
in
rr
n
r
i