A SERVICE OF

logo

Convention Power indicator
pattern
Condition
CAUTION: When correcting a PSU mismatch, replace only
the PSU with the flashing indicator. Swapping the PSU to
make a matched pair can result in an error condition and
unexpected system shutdown. To change from a High
Output configuration to a Low Output configuration or vice
versa, you must power down the system.
CAUTION: AC PSU support both 220 V and 110 V input
voltages with the exception of Titanium PSU, which support
only 220 V. When two identical PSU receive different input
voltages, they can output different wattages, and trigger a
mismatch.
CAUTION: If two PSU are used, they must be of the same
type and have the same maximum output power.
CAUTION: Combining AC and DC PSU is not supported and
triggers a mismatch.
D Not lit Power is not connected.
Documentation matrix
The documentation matrix provides information on documents that you can refer to for setting up and
managing your system.
Table 1. Documentation matrix
To... See the...
Install your system into a rack Rack documentation included with your rack
solution.
Set up your system and know the system technical
specifications
Getting Started With Your System that shipped with
your system or see Dell.com/poweredgemanuals.
Install the operating system Operating system documentation at Dell.com/
operatingsystemmanuals
Get an overview of the Dell Systems Management
offerings
Dell OpenManage Systems Management Overview
Guide at Dell.com/openmanagemanuals >
OpenManage software
Configure and log in to iDRAC, set up managed
and management system, know the iDRAC
features and troubleshoot by using iDRAC
Integrated Dell Remote Access Controller User's
Guide at Dell.com/idracmanuals
Know about the RACADM subcommands and
supported RACADM interfaces
RACADM Command Line Reference Guide for
iDRAC at Dell.com/idracmanuals
Launch, enable and disable Dell Lifecycle
Controller, know the features, use and
troubleshoot Dell Lifecycle Controller
Dell Lifecycle Controller User’s Guide at Dell.com/
idracmanuals
23