A SERVICE OF

logo

24
PQ-8P, PQ-8S
Table 4-4. Tests/Diagnostic Switch Settings.
Tests/Diagnostic SW1:1 SW1:2 SW1:3 SW1:8
Twinax Diagnostic ||||
Restore Factory |||o
Defaults
Self-Test Any setting corresponding to |
a twinax address 0-6
EBCDIC Hex Dump |
Operating Mode o
Tests/Diagnostic SW1:4 SW1:5 SW1:6 SW1:7
ASCII Hex Dump ||||
The first three functions (Twinax
Diagnostics, Restore Factory
Defaults, Self-Test) are only
performed if the configuration
switches are set as indicated when
the PQ-8 is powered up. In the case
of the self-test, the PQ-8 prints a self-
test at power-up and then should be
powered off. Refer to Chapter 7 for
more information.