Yamaha FX10RTRSY Offroad Vehicle User Manual


 
Periodic maintenance and adjustment
68
INTERNAL: Drink large quantities of wa-
ter or milk. Follow with milk of magne-
sia, beaten egg, or vegetable oil. Call
physician immediately.
EYES: Flush with water for 15 minutes
and get prompt medical attention.
Batteries produce explosive gases. Keep
sparks, flame, cigarettes, etc. away. Venti-
late when charging or using in an en-
closed space. Always shield your eyes
when working near batteries.
KEEP OUT OF THE REACH OF CHILDREN.
Charge or have a Yamaha dealer charge the
battery as soon as possible if it seems to have
discharged. Keep in mind that the battery
tends to discharge more quickly if the snow-
mobile is equipped with electrical accesso-
ries.
WARNING
EWS00610
Never smoke around the battery while it
is being charged. Sparks may ignite the
hydrogen gas created by the battery.
Disconnect the negative lead first, then
the positive lead from the battery.
Connect the positive lead first, then the
negative lead to the battery when install-
ing the battery.
Never connect the battery to or discon-
nect it from the snowmobile while it is
being charged. Sparks may ignite the
hydrogen gas created by the battery.
Make sure that the battery terminals are
tight.
NOTICE
ECS00842
To charge a VRLA (Valve Regulated
Lead Acid) battery, a special (constant-
voltage) battery charger is required. If
you do not have access to a constant-
voltage battery charger, have a Yamaha
dealer charge your battery. Using a con-
ventional battery charger will damage
the battery.
Do not charge the battery quickly.
ESU12872
Replacing a fuse
WARNING
EWS00550
Be sure to use the specified fuse. A wrong
fuse could cause electrical system dam-
age or A FIRE HAZARD.
NOTICE
ECS00631
Be sure to turn the main switch to the off
position and disconnect the negative bat-
tery lead to prevent accidental short-cir-
cuiting.
1. Remove the shroud and the right side
cover. (See page 44 for removal proce-
dures.)
2. Disconnect the negative battery lead.
3. Replace the blown fuse with one of the
proper amperage.
1. Negative battery lead
1