Vintage 551170 Automobile User Manual


 
IMPORTANT NOTICE-PLEASE READ
FOR MAXIMUM SYSTEM PERFORMANCE VINTAGE AIR RECOMMENDS THE FOLLOWING:
LUBRICANT CAPACITIES:
134a SYSTEM
R-12 SYSTEM
CHARGE WITH 2.0 lbs. OF REFRIGERANT
CHARGE WITH 1.8 lbs.
(1lbs. 12ozs) OF REFRIGERANT
NEW COMPRESSOR - NO ADDITIONAL OIL NEEDED
USED COMPRESSOR - CONSULT VINTAGE AIR
SERVICE INFO:
SAFETY SWITCHES:
ATTENTION: SYSTEM COMPONENTS: THE COMPRESSOR, EVAPORATOR, CONDENSER & DRIER ARE CAPPED.
CAPS MAY BE UNDER PRESSURE WITH DRY NITROGEN; BE CAREFUL REMOVING CAPS. DO NOT REMOVE CAPS
PRIOR TO INSTALLATION. REMOVING CAPS PRIOR TO INSTALLATION WILL CAUSE COMPONENTS TO COLLECT
MOISTURE AND LEAD TO PREMATURE FAILURE AND REDUCED PERFORMANCE.
EVACUATE THE SYSTEM FOR 35-45 MINUTES WITH SYSTEM COMPONENTS (DRIER, COMPRESSOR, EVAPORATOR
AND CONDENSER) AT A TEMPERATURE OF AT LEAST 85° F. ON A COOL DAY THE COMPONENTS CAN BE HEATED
WITH A HEAT GUN OR BY RUNNING THE ENGINE WITH THE HEATER ON BEFORE EVACUATING. LEAK CHECK
AND CHARGE TO SPECIFICATIONS.
YOUR VINTAGE AIR SYSTEM IS EQUIPPED WITH A BINARY PRESSURE SAFETY SWITCH. A BINARY SWITCH
(11078-VUS) DISENGAGES THE COMPRESSOR CLUTCH IN CASE OF EXTREME LOW PRESSURE CONDITION
(REFRIGERANT LOSS) OR EXCESSIVELY HIGH HEAD PRESSURE (406 PSI), TO PREVENT COMPRESSOR DAMAGE
OR HOSE RUPTURE. A TRINARY SWITCH (11076-VUS) COMBINES HI/LO PRESSURE PROTECTION WITH AN
ELECTRIC FAN OPERATION SIGNAL AT 254 PSI., AND MAY BE SUBSTITUTED FOR USE WITH ELECTRIC
CONDENSER FANS. COMPRESSOR SAFETY SWITCHES ARE EXTREMELY IMPORTANT SINCE AN A/C SYSTEM
RELIES ON REFRIGERANT TO CARRY LUBRICATION THROUGH THE SYSTEM.
THIS KIT DOES NOT CONTAIN HEATER HOSE. YOU MUST PURCHASE 8 FEET OF 5/8” DIA.
HEATER HOSE FROM VINTAGE AIR(31800-VUD) OR FROM YOU LOCAL PARTS RETAILER
VINTAGE AIR SYSTEMS ARE DESIGNED TO OPERATE WITH R134a or R-12
REFRIGERANT ONLY ! USE OF ANY OTHER REFRIGERANTS RISKS A DANGER OF FIRE
AND COULD DAMAGE EITHER YOUR AIR CONDITIONING SYSTEM OR YOUR VEHICLE.
USE OF ANY OTHER REFRIGERANTS WILL VOID ALL WARRANTIES OF
THE AIR CONDITIONING SYSTEM AND COMPONE NTS. USE OF THE PROPER
TYPE AND AMOUNT OF REFRIGERANT IS CRITICAL TO PROPER SYSTEM
OPERATION. VINTAGE AIR RECOMMENDS OUR SYSTEMS BE CHARGED BY
WEIGHT WITH A QUALITY CHARGING STATION OR SCALE.
REFRIGERANT CAPACITIES FOR VINTAGE AIR SYSTEMS
(FOR OTHER SYSTEMS, CONSULT MANUFACTURER GUIDELINES)
1969-70 MUSTANG
w/o FACTORY AIR
4
1969-70 MUSTANG w/o AC GEN IV
901271 REV A 2/11/08, 69-70 MUSTANG w/o AC GEN IV EVAP INSTR PG 4 OF 26