Scytek electronic 5500 Automobile Alarm User Manual


 
Page 24 - Precision Pro
Automatic Start Mode
Automatic Start feature has three modes that will start the vehicle every one or two hours.
1. Timer Only Mode (Oprates for 24 hour priod only)
(factory default)
The Automatic Start feature starts the vehicle automatically every one or two hours and runs for
the preset Run Time. (15 or 25 min)
Auto Start On Timer Mode:
1. Turn Ignition switch Off and wait for 3 seconds.
2. Turn Ignition switch On and Off three times ending with Ignition in Off position
3. Press the Valet switch immediatly after.
parking lights will flash indicating that the Auto Start mode has been activated.
2. Low Temperature Start Mode**
The Automatic Start feature starts the vehicle automatically for a preset Run Time every one or two
hours if the temperature in the vehicle drops bellow the preset value (factory default -15
o
F).
3. High Temperature Start Mode (Oprates for 24 hour priod only)**
The Automatic Start feature starts the vehicle automatically for a preset Run Time every one or two
hours if the temperature in the vehicle exceeds the preset value (factory default 138
o
F).
** See the
2-way LCD Remote Transmitter section for
Auto Start Cold or Hot Temperature Activation.
To disable Auto Start function
Do one of the following:
· Turn ignition On.
· Arm*/Lock and then Disarm*/Unlock the system
· Alarm* or Panic the system
Time of day Auto Start Mode
(
Oprates for 24 hour priod only)
Precision Pro internal real time clock has two settings to autostart on a preset time. This feature is enabled only using the
color remote pager. Please refer to the
System Clock Sync START Time
setting of the manual to set the time. And
Set
System Parameters
ENABLE AUTOSTART 1, ENABLE AUTOSTART 2.
Turbo Timer Feature
The optional Turbo Timer feature allows vehicles with turbocharged engines to remain running after the
ignition key is removed, for proper cool-down of the turbocharger. The Turbo Timer feature requires
connection to the vehicle’s parking brake wire.
To activate the Turbo Timer feature:
1. Leave the engine running after parking the vehicle.
2. Set the vehicle’s parking brake.
· The Turbo Timer will begin a two-minute run cycle to allow the turbocharger to cool down.
3. Turn OFF the ignition and exit the vehicle.
To deactivate the Turbo Timer feature:
1. Press and hold the brake pedal.
2. Release the emergency/parking brake.
3. Re-apply the vehicle’s parking brake.
· The Turbo Timer countdown will automatically stop and the engine will shutdown.
WARNING: the Turbo Timer feature is not intended for use inside garages or other non-ventilated areas.
Make sure to deactivate the Turbo Timer feature when parking in such areas.