4. Door Lock Pulse Length. Selects between a 1-second and a 3-second output for door locking and
unlocking. Program to 3 seconds for vehicles equipped with vacuum door locking systems.
5. Aux 2 Auto Activate with Arm. When selected, the Auxiliary 2 output will activate when the system
is armed. This feature can be used to roll-up windows, close sunroofs, activate accessories, etc.
6. Auxiliary 1 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 1.
Momentary operation provides an output for as long as the transmitter button is pressed.
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and remains
on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be
programmed to output for 1 second up to 255 seconds.
7. Auxiliary 2 Mode. Selects from Momentary, Timed, or Latched operation for Auxiliary 2.
8. Disarm with Auxiliary 1. When selected, activating the Auxiliary 1 output (usually used to open the
trunk) will disarm the alarm.
9. Start in Valet Mode. Selects whether or not the vehicle can remote start while in the valet mode.
10. Lock After Start. When selected, the doors will automatically lock after remote starting.
11. Lock After Shutdown. When selected, the doors will automatically lock after remote shutdown.
12. Engine Run Time. Selects between 15 or 25 minutes for the remote start run cycle.
13. Automatic Start Mode. Selects between every two hours or every hour for the automatic engine
starting feature.
Branch Feature Button 1 (default) Button 2 Button 3
1. Ignition Door Locking On Off
2. Ignition Door Unlocking Unlock All Unlock Driver Only Off
3. Door Unlock Pulse Single Double
4. Door Lock Pulse Length 1 second 3 seconds
5. Aux 2 Activate on Lock Off On
6. Aux 1 Mode Pulsed Timed Latched
7. Aux 2 Mode Pulsed Timed Latched
8. not used
9. Start in Valet Mode Disable Enabled
10. Lock after Start On Off
11. Lock after Shutdown On Off
12. Engine Run Time 15 minutes 25 minutes
13. Automatic Start Mode 2 hours 1 hour
14. Engine Sense Mode Tachless Tach Monitor
15. Remote Start Program RPM Learn Gas Engine Diesel Engine
16. FM Transmitter Program not used FM Remote Learn
17. Ignition 2 Output Program Ignition 2 Output Accessory 2 Output Starter 2 Output
18. Horn Honk Output Horn Output Ignition 3 Output
19. Turbo Mode Disabled Enabled