Pride Mobility none Automobile Accessories User Manual


 
16 Basic Operation Instructions
Europa Controller www.pridemobility.com
Table 1. Error Codes
Error Fault Diagnosis Solution
Code
1 DX Module Fault An auto download has occurred. See your authorized Pride Provider.
The Europa is not correctly programmed.
The connection between the power module
and the joystick module may be faulty.
2 DX Accessory Fault The accessory module (CLAM) has a fault. See your authorized Pride Provider.
3 Left Motor (or connection) The connection between the power module Check left motor writing.
Fault and the left motor is either open or is
shorted or the motor itself is shorted.
4 Right Motor (or connec- The connection between the power module Check right motor writing.
tion) Fault and the right motor is either open or is
shorted or the motor itself is shorted.
5 Left Park Brake (or The connection between the power module Check motor/brake wiring.
connection) Fault and the left park brake is either open or
shorted or the motor brake itself is shorted.
6 Right Park Brake ( or The connection between the power module Check motor/brake wiring.
connection) Fault and the right motor brake is either open or
shorted or the motor brake itself is shorted.
7 Low Battery Fault Battery voltage has fallen below 17VDC. Check that the battery wiring is secure.
8 Over-voltage Fault The battery voltage has exceeded 32VDC. Check that the battery wiring is secure.
9 CANL Fault The DX Bus cable has a short or an open. See your authorized Pride Provider.
10 CANH Fault The DX Bus cable has a short or an open. See your authorized Pride Provider.
11 Stall Timeout The motor has been close to or at the Turn unit off, then on.
programmed current limit.
12 Module Mismatch There is an incompatibility between the DX See your authorized Pride Provider.
modules in the system.