12 Basic Operation Instructions
Europa Controller www.pridemobility.com
System Status Light
The system status light is normally on when the system is powered up, and off
when the system is powered down. This light will flash if there is an internal fault,
or if an OONAPU fault has occurred. See Out Of Neutral At Power Up.
Magnetic Locking Area
Your power chair is equipped with a feature that enables you to lockout unautho-
rized users. For this function, you will need the magnetic key supplied with your
power chair. If you lose this key, contact your authorized Pride Provider.
To enable the lockout system:
1. Hold the magnetic key on or near the key symbol. The system will beep and
automatically turn off.
NOTE: None of the remote lights should be lit.
2. Press the on/off key to turn on the power chair. The key symbol will flash, but
you will not be able to drive your power chair. This means that it is still locked.
3. Hold the magnetic key on or near the key symbol again to unlock the system.
When the key symbol stops flashing, you may turn on the power chair.
NOTE: If you turn on the power chair while it is locked and do not un-
lock it after one minute, the power chair will automatically turn off itself.
Battery Condition Meter
The battery condition meter consists of six lights arranged in an arc over the bat-
tery icon. From left to right, the first two are red, the second two are orange, and
the last two are green. These lights give you an accurate indication of your usable
battery capacity. If the battery has at least 85% of its rated capacity, all of the
lights will be on. As the battery voltage drops, the number of lights reduces from
right to left. When the battery capacity drops to 10% or below, all of the lights will
flash once every second.
NOTE: When the battery capacity drops to below 21V (typically two lights),
the controller will reduce power chair performance to conserve battery
power.