Hamilton Sundstrand Company eXVG Automobile Parts User Manual


 
Register
Number
XVG/eXVG Parameters
Name
Write
Access
Description Type
5014 5015 IDM_LVDTSCALEFCT RO Obsolete U32
5016 5017 IDM_RUNTMHRS RO Run Time Hours since last power on U32
5018 5019 IDM_FLOCTLPOSOUT RO Calculated flow control position demand, 683-3413 U32
5020 5021 IDM_TOTALHRS RO Total Running Hours U32
5022 5023 IDM_TOTHRSIG RO Total Running Hours Cleared Signature U32
5024 5025 IDM_FLOWLIMPOS RO Flow Limiting Pos Demand Output, 0-3413 U32
5026 5027 IDM_FTOTALHRS RO Fault Log, Total Hours of fault log record U32
5028 5029 IDM_FRUNTMHRS RO Fault Log, Run Time Hours of fault log U32
5030 5031 IDM_ADCSTATFLGS RO
Bit field to indicate analog input over-range
Bit0 = AdcA0
Bit1 = AdcB0
Bit0 = AdcA1
Bit1 = AdcB1
Bit0 = AdcA2
Bit1 = AdcB2
Bit0 = AdcA3
Bit1 = AdcB3
Bit0 = AdcA4
Bit1 = AdcB4
Bit0 = AdcA5
Bit1 = AdcB5
Bit0 = AdcA6
Bit1 = AdcB6
U32
5032 5033 IDM_FAULTLATCHL W3
Latched Faults, format same as
IDM_FAULTFLAGSL, cleared at power on
U32
5034 5035 IDM_FAULTFLAGSL RO
Active Faults: Bit0=3.3V, Bit1=Tracking,
Bit2=GasTemp Range, Bit4=Input Pressure,
Bit5=Output Pressure, Bit6=LVDT, Bit7=Setup,
Bit8=Flow Setup Bit10=Overpressure,
Bit11=GasTemp shutdown, Bit12=+15V supply,
Bit13=Neg15V supply, Bit14=Amb Temp,
Bit15=Watchdog, Bit16=Advanced diagnostics,
Bit 17=Communication
U32
5036 5037 IDM_TRS RO Total seconds of operation (valve open) U32
5038 5039 IDM_OCC RO
Over-current count, number of sample events with
motor current > IDM_OCT
U32
5040 5041 IDM_MMG RO
Modbus messages good, total valid messages
received.
U32
5042 5043 IDM_MMI RO
Modbus messages invalid, total invalid messages
received (invalid data or request command)
U32
5044 5045 IDM_MMB RO
Modbus messages bad, total messages received with
bad CRC.
U32
5046 5047 IDM_TA RO
Thermal age, estimated electronics age with
temperature factor, in seconds.
U32
5048 5049 IDM_PRS RO Histogram array parameter for PressureRatio, seconds U32
5050 5051 IDM_GTS RO Histogram array parameter for GasTemp, seconds U32
5052 5053 IDM_TAS RO
Histogram array parameter for electronics
temperature, seconds
U32
5054 5055 IDM_IPS RO Histogram array parameter for InletPressure, seconds U32
29