Hamilton Sundstrand Company eXVG Automobile Parts User Manual


 
Register
Number
XVG/eXVG Parameter
Name
Write
Access
Description Type
Default
Value
3521 IDM_FLOWCTRLEN W4
Flow Control Enable: 0=Baseline (Stroke
Mode) Valve, 1=FM / FC / FL valve
U16
1
3522 IDM_FLTTMCURRENT W4
Current fault persist time: x20mS, range 0-
32767
U16
32767
3523 IDM_FLTTMTMPSHUT W4
Over temperature shutdown fault persist time:
x20mS, range 0-32767
U16
500
3524 IDM_SOLIMAX W4 Solenoid Current Limit: range 1-4095 U16 3500
3525 IDM_AO0CFG W2
Analog Output Zero Configuration:
0=Disabled
1=Position Feedback (0-MaxStroke)
2=Measured Flow (0-Flow Range)
3=Corrected Output Pressure (0-500 PSIA)
4=Input Pressure (0-500 PSIA)
5=Output Pressure (0-500 PSIA)
6=Gas Temperature (-40 to 150 Deg. C)
7=Test mode to write directly to AO with
ADC gain/offset via IDM_AOUTx
U16 1
3526 IDM_AO1CFG W2 Same as IDM_AO0CFG U16 0
3527 IDM_AO2CFG W2 Same as IDM_AO0CFG U16 0
3528 IDM_SELFCALENABLE W4
Auto Zero Calibration Enable: 0=Disabled,
1=Enabled
U16 0
3529 IDM_DPENABLE W4
Differential Pressure Measurement Enable (3
PSIA and higher):
0=show actual flow on all pressures except
reverse flow conditions.
1=pressure differential less than 3.0 PSIA
will report 0 PPH flow.
U16 1
3530 IDM_FLTTMPOS15V W4
Positive 15V source fault persist time:
x20mS, range 0-32767
U16 3
3531 IDM_FLTTMNEG15V W4
Negative 15V source fault persist time:
x20mS, range 0-32767
U16 3
3532 IDM_FLTTMTEMPAMB W4
Ambient/electronics fault persist time:
x20mS, range 0-32767
U16 50
3533 IDM_FLOWCALCURVE W4 Flow Calibration Curve, range 0 to 100 U16 0
3534 IDM_ELECTINTRFC W4 Electrical interface configuration number,
range 0 to 3
U16 0
3535 IDM_FLANGEACC W4 Flange accessory configuration number,
range 0 to 3
U16 0
3536 IDM_LVDTEXSCALE W4 LVDT excitation output scale factor. Re-tune
if IDM_LVDTPHASE not a multiple of 4.
Units of %. Range: 0 to 200
U16 100
3537 IDM_OCT W4
Motor over-current threshold for AdvDiag
over-current event counter. Range: 0-4095
U16 3850
3538 IDM_CLTHRESH W4
Communication lost fault threshold time,
units of seconds. Fault disabled if = 0.
Range: 0 to 500
U16 0
3539 IDM_DJSUMDB W4
Demand jitter accumulator dead-band, units
of demand counts. Range: 0 to 200
U16 4
3540 IDM_SLAVEADDR W2
Modbus slave (node) address.
Range: 1 to 247
U16 1
13