Hamilton Sundstrand Company eXVG Automobile Parts User Manual


 
Register
Number
XVG/eXVG Parameter
Name
Write
Access
Corresponding CdA value Type
Default
Value
6238 6239 IDM_CDATBLPR7S14 W4 0.618915975 U32 10383687
6240 6241 IDM_CDATBLPR8S0 W4 0.017536998 U32 294222
6242 6243 IDM_CDATBLPR8S1 W4 0.034340978 U32 576146
6244 6245 IDM_CDATBLPR8S2 W4 0.045249999 U32 759169
6246 6247 IDM_CDATBLPR8S3 W4 0.075426996 U32 1265455
6248 6249 IDM_CDATBLPR8S4 W4 0.11294198 U32 1894852
6250 6251 IDM_CDATBLPR8S5 W4 0.154013991 U32 2583926
6252 6253 IDM_CDATBLPR8S6 W4 0.191594005 U32 3214414
6254 6255 IDM_CDATBLPR8S7 W4 0.233344972 U32 3914879
6256 6257 IDM_CDATBLPR8S8 W4 0.258821011 U32 4342296
6258 6259 IDM_CDATBLPR8S9 W4 0.302787006 U32 5079923
6260 6261 IDM_CDATBLPR8S10 W4 0.367821991 U32 6171029
6262 6263 IDM_CDATBLPR8S11 W4 0.415814996 U32 6976218
6264 6265 IDM_CDATBLPR8S12 W4 0.473388016 U32 7942133
6266 6267 IDM_CDATBLPR8S13 W4 0.527272999 U32 8846173
6268 6269 IDM_CDATBLPR8S14 W4 0.584348023 U32 9803733
6270 6271 IDM_CDATBLPR9S0 W4 0.017027974 U32 285682
6272 6273 IDM_CDATBLPR9S1 W4 0.033367991 U32 559822
6274 6275 IDM_CDATBLPR9S2 W4 0.043686986 U32 732946
6276 6267 IDM_CDATBLPR9S3 W4 0.073494017 U32 1233025
6278 6269 IDM_CDATBLPR9S4 W4 0.107271016 U32 1799709
6280 6281 IDM_CDATBLPR9S5 W4 0.150669992 U32 2527823
6282 6283 IDM_CDATBLPR9S6 W4 0.183247983 U32 3074391
6284 6285 IDM_CDATBLPR9S7 W4 0.231404006 U32 3882315
6286 6287 IDM_CDATBLPR9S8 W4 0.25821501 U32 4332129
6288 6289 IDM_CDATBLPR9S9 W4 0.281709015 U32 4726293
6290 6291 IDM_CDATBLPR9S10 W4 0.344421983 U32 5778442
6292 6293 IDM_CDATBLPR9S11 W4 0.391855001 U32 6574236
6294 6295 IDM_CDATBLPR9S12 W4 0.445888996 U32 7480776
6296 6297 IDM_CDATBLPR9S13 W4 0.501824021 U32 8419210
6298 6299 IDM_CDATBLPR9S14 W4 0.544903994 U32 9141972
Table 20: CdA-Pressure Ratio Table Parameters
9.1.6 Flow Limiting Mode Parameters
The following table is used to define the Flow Limiting Mode schedule. The 5-point
Flow Limiting Mode Table defines the minimum and maximum flow limits by
interpolation for a particular backpressure.
Valid Flow Limiting Mode Table Backpressure values are in the range 0.0 - 498.0, 32 bit
floating point format. Valid Flow Limiting Mode Table Minimum Flow values are in the
range 0.0 - 20000.0, 32 bit floating point format. Valid Flow Limiting Mode Table
Maximum Flow values are in the range 0.0 - 20000.0, 32 bit floating point format.
23