MAINTENANCE
Battery
Battery Charging
The following battery charging instructions apply only to the installa-
tion of an activated, sealed battery. Read all instructions before proceed-
ing with the installation of this battery.
A sealed battery is already filled with electrolyte. It has been sealed and
is fully charged at the factory. Always keep a sealed battery fully
charged.
• DO NOT pry the sealing strip off.
• DO NOT add any other fluid to this battery.
• A fully charged battery will register 12.8 V or higher.
1. Check battery voltage with a
voltmeter or multimeter.
2. If voltage is low, recharge the
battery at 1.2 amps or less until
the voltage is 12.8 or greater.
Tip: When using an automatic charger,
refer to the charger manufacturer's
instructions for recharging. When
using a constant current charger,
follow the guidelines below.
Always verify battery condition before and 1-2 hours after the end of
charging.
State of
Charge
Voltage Action
Charge Time
(Using constant current
charger @ standard amps
specified on top of battery)
100% 12.8-13.0 volts None, check at 3
mos. from date of
manufacture
None required
75%-100% 12.5-12.8 volts May need slight
charge, if no
charge given,
check in 3 months
3-6 hours
50%-75% 12.0-12.5 volts Needs charge 5-11 hours
25%-50% 11.5-12.0 volts Needs charge At least 13 hours,
verify state of charge
0%-25% 11.5 volts or less Needs charge with
desulfating charger
At least 20 hours