Lowrance electronic LMS-480M GPS Receiver User Manual


 
29
4. Press to select
CALIBRATE and press ENT. The Device Calibration
menu will appear.
5. Highlight
NUM PTS, press ENT and select 3. Press ENT.
6. Make sure your tank is empty, then highlight FLUID LEVEL and press
ENT
. Select EMPTY LEVEL and press ENT.
7.
Select CALIBRATE and press ENT. The following message will appear:
Empty Level Calibration Completed. Press
ENTER.
8.
Add half a tank of fuel, highlight FLUID LEVEL and press ENT. Select
H
ALF LEVEL and press ENT.
Num Pts menu with 5-point calibration selected (left). Half level selected on
Fluid Level menu
(center). Calibration Done window (right).
9.
Select CALIBRATE and press ENT. The following message will appear:
Half Level Calibration Completed. Press
ENT.
10. Fill up the tank, then
highlight FLUID LEVEL and press ENT. Select
F
ULL LEVEL and press ENT.
11.
Highlight CALIBRATE and press ENT. The following message will ap-
pear: Full Level Calibration Completed. Press
ENT, then press EXIT re-
peatedly to get back to the main display.
5-Point Calibration
5-point calibration is best suited tanks that vary greatly in shape from
top to bottom. You can begin calibration at any point in the 5-point cali-
bration process. We recommend starting calibration with an empty
tank. In a five-point calibration you will set five points: Empty Level, 1
Qtr Level, Half Level, 3 Qtr Level and Full Level.
In a 5-point calibration, you will have four calibration points left after
calibrating your tank's Empty Level. To figure out how much fuel you
should add for the remaining steps of the calibration process, divide the
total capacity of you tank by four. So, if you have a 40-gallon tank, each
quarter tank will equate to 10 gallons.