Lowrance electronic LMS-480M GPS Receiver User Manual


 
27
To calibrate an EP-10 Fuel Flow:
10. If calibration is necessary, press MENU|MENU, select NMEA 2000 and
press
ENT.
11. Highlight
FUEL MANAGEMENT and press ENT.
12. Select
TANK LOCATION and press ENT to choose the location of the tank
connected to selected fuel flow. Press
ENT.
13. Highlight
FILL TANK and press ENT. The following message will ap-
pear: Are you sure you wish to Fill Tank? Select
YES and press ENT.
14. The following message will appear: Do you wish to re-calibrate the
device? Select
YES and press ENT.
15. Repeat these steps for each EP-10 Fuel Flow you want to calibrate.
To Reset Calibration:
1. Press MENU|MENU, select NMEA 2000 and press ENT.
2. Highlight
FUEL MANAGEMENT and press ENT.
3. Highlight
ENGINE SELECT and press ENT. The Engine Select menu will
appear with up to four options: All Engines, Port, Center and Star-
board. Selecting All Engines will reset calibration for all engines back
to factory defaults.
4. Select All Engines or the engine connected to the desired device and
press
ENT.
5. Highlight
RESET CALIBRATION and press ENT. The following message
will appear: Are you sure you wish to Reset Calibration?
6. Highlight
YES and press ENT. Press EXIT repeatedly to get back to the
main display.
EP-15 Fluid Level Calibration
The default calibration for the EP-15 Fluid Level is just as accurate as
standard fluid level gauges. If, however, the tank has an irregular
shape or greater accuracy is needed, calibration is recommended. There
are three calibration options: 2-Point, 3-Point and 5-Point.
2-Point Calibration
A 2-point calibration is best suited for rectangular or square-shaped
tanks, where the capacity of the top half of the tank matches the capac-
ity in the lower half of the tank. In a two-point calibration, you will set
two points, one each for empty and full levels. You can begin calibra-
tion at either of the two points, but we recommend starting with an
empty tank. You will fill the tank to complete calibration.
1. Press
MENU| MENU, use to select NMEA 2000 and press ENT.
2. Highlight
BUS SETUP and press ENT, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page.