AUTOMATIC AIR GREASE GUN
MODEL 1162
TO CONVERT GUN TO ALLOW FILLING FROM
BULK CONTAINER OR FILLER PUMP
1) Unscrew the container cap from the container tube. Pull
on the follower handle to extract the follower and spring
from the container tube.
2) Grasp follower between thumb and forenger and ip the
follower lip from the rear to the front side.
NOTE: The follower resembles a cup. When the gun is
assembled for use with bulk lubricant, the cup
opens toward the head assembly.
3) Reassemble follower into container tube and position
with the follower handle so that the container cap can be
tightened onto the container tube.
Fig. 3
TO FILL THE GUN FROM BULK CONTAINER
1) Remove head and plunger assembly from container
tube.
2) Pack lubricant into cavity of the head and plunger
assembly.
3) Insert the open end of the container tube into lubricant.
Slowly pull the follower handle back while pushing the
container tube deeper into the lubricant to prevent air
pockets from being pulled into the container tube.
4) When the follower rod is fully extended, pull it sideways
to latch the rod groove into the keyhole slot in the
container cap.
5) Loosely assemble the head and plunger assembly to the
lled container tube. Release the follower rod from the
container cap and disengage the follower rod from the
follower by rotating the follower handle. Push the follower
rod into the container. Slowly unscrew the container tube
from the head and plunger assembly until lubricant
oozes from the interface. Tighten container tube into the
head and plunger assembly.
TO FILL THE GUN WITH A FILLER PUMP
Engage the follower rod with the follower by rotating the
follower handle. Insert the gun ller nipple into the ller
pump socket. Operate the ller pump to ll the container.
When the follower rod groove is exposed, the container is
lled (follower rod will be extended approximately 8 inches
or 20 cm). Disengage the follower rod from the follower by
rotating the follower handle. Push the follower rod into
the container.
Fig. 4
Fig. 5
TO EXPEL AIR POCKETS
1) Withdraw the follower rod from the grease tube
assembly cap and engage it with the follower by rotating
the follower handle . Exert the force on the follower handle
after opening the vent/ller tting (18) (see Fig. 6).
2) Pull the trigger in short bursts to operate gun until trapped
air is expelled. Disengage the follower rod from the fol-
lower by rotation the follower handle. Push the follower
rod into the grease tube assembly.
3) If the step 2 fails, unscrew the grease tube assembly1-1/2
turns from the pump assembly.
4) Exert force on the follower handle until lubricant oozes
from the grease tube assembly and pump assembly
interface.
5) Tighten grease tube assembly into the pump assembly.
Disengage the follower rod from the follower by rotation
the follower handle. Push the follower rod into the grease
tube assembly.