Husky 647016 Automobile Parts User Manual


 
Installation
12 313597E
Fluid Outlet Line
See FIG. 3 through FIG. 5, pages 11 through
13.
1. Use grounded fluid hoses (G, K). See
Grounding, page 8.
2. The pump fluid outlet is 1 in. npt(f). Screw
the fluid fitting into the pump outlet
securely.
3. A fluid drain valve (H) is required in your
system to relieve pressure in the hose and
dispense valve. Install the valve close to
the pump fluid outlet.
4. Install a shutoff valve (J) in the fluid outlet
line.
Fluid Inlet and Outlet Ports
NOTE: Remove and reverse the manifold(s) to
change the orientation of inlet or outlet port(s).
Follow Torque Instructions, page 18.
The fluid inlet and outlet manifolds each have
four 1 in. npt(f) threaded ports. Close off the
unused ports, using the supplied plugs.
FIG. 4. Gear oil evacuation, typical installation
A
B
D
E
C
G
H
J
K
L
M
N
R
Key:
A Air supply line
B Bleed-type master air
valve (required for pump)
C Air filter/regulator
assembly
D Air inlet
E Master air valve (for
accessories)
G Fluid suction line, flexible
hose
H Fluid drain valve
(required)
J Fluid shutoff valve
K Waste oil line (to storage
tank)
L Fluid line, flexible hose
M Control valve
N Suction wand
R Ground wire (required, see
page 8 for installation in-
structions)
ti14222b