Furuno FAR2167DS-BB Radar Detector User Manual


 
2-4
7. Using the terminal opener provided, connect cores (except coaxial cable) to their appropriate
locations on TB801 on the TB Board. Refer to the interconnection diagram for wiring details.
8. Connect the coaxial cable to TB802, referring to the right-hand illustration below..
How to wire WAGO connector
9. Attach crimp-on lug (FV5.5-4) to the shield of the signal cable and fasten it with the screw at
the location specified in the illustration on the preceding page.
10.Process unused cores as follows:
a) Slip shrink tubing onto cores and heat.
b) Bind unused cores with cable tie.
11.Unfasten the gland nut for the HV cable and remove gasket, flat washers (3 pcs.) and gland
cap. (The gland cap may be discarded.)
12.Fabricate the HV cable as shown below.
How to fabricate HV cable TYPCY-1.5
Fastening coaxial cable
NOTICE
Procedure
1. Twist core.
2. Insert terminal opener as shown and
push down.
3. Insert core into hole.
4. Release terminal opener.
5. Pull wire to confirm that it is firmly in
place.
Terminal opener
Wiring WAGO connector
WAGO connector
Wire
Twist
Push down.
Fasten BARE conductor. Do not use
crimp-on lug, to prevent increased
contact resistance.
Fasten shield
by clamp.
Fasten conductor with screw.
Taping
20 mm
5 mm
Sheath
Armor
Vinyl
sheath
L
Conductor
S = 1.50 mm
2
φ = 1.56 mm
Armor
Sheath
SECTIONAL VIEW
6
L: 300 mm (red)
L: 370 mm (black, white)