Table 3. Additional Specifications (Action Air-to-Open)
Size
Spring Set/
Quantity
Travel Spring Range
Effective Diaphragm Area
(Note 1)
Maximum Output Thrust
(Maximum Actuator Stem
Force) (Note 2)
Quantity
mm Inch Bar Psig cm
2
Inches
2
N Lb
217/3
0.5 - 1.3 7 - 19 170 26.4 780 170
30
217/3
218/5
16
-
1.4 - 2.2 20 - 32 170 26.4 2360 530
30
218/5
218/7
16
2.0 - 3.1 29 - 45 170 26.4 3360 760
217/3
0.3 - 1.3 4 - 19 175 27.1 550 120
30E
217/3
218/5
- 0.75
1.2 - 2.2 17 - 32 175 27.1 2180 490
30E
218/5
218/7
0.75
1.8 - 3.1 26 - 45 175 27.1 3110 700
219/3
0.6 - 1.4 9 - 20 410 63.6 2450 550
34
219/3
212/5
16 -
1.1 - 1.9 16 - 28 410 63.6 4610 1040
34
212/5
212/7
16
1.6 - 2.7 23 - 39 410 63.6 6560 1480
219/3
0.4 - 1.4 6 - 20 420 65.1 1880 420
34E
219/3
212/5
- 0.75
1.0 - 1.9 15 - 28 420 65.1 4120 930
34E
212/5
212/7
0.75
1.4 - 2.7 20 - 39 420 65.1 5870 1320
212/3
0.4 - 1.3 6 - 19 450 69.8 1880 420
40
212/3
213/6
32 -
0.8 - 1.8 12 - 26 450 69.8 3640 820
40
213/6
214/7
32
1.2 - 2.4 17 - 35 450 69.8 5530 1240
212/3
0.5 - 1.3 7 - 19 440 68.2 2200 500
212/3
213/6
- 1.125
0.9 - 1.8 13 - 26 440 68.2 3970 890
213/6
214/7
1.125
1.3 - 2.4 19 - 35 440 68.2 5920 1330
213/4
0.4 - 1.1 6 - 16 410 63.6 1560 350
40E
213/4
214/5
-
15
0.7 - 1.6 10 - 23 410 63.6 3010 680
40E
214/5
214/7
1
.
5
1.0 - 2.3 15 - 33 410 63.6 4270 960
213/4
0.2 - 1.2 3 - 17 440 68.2 1060 240
213/4
214/5
- 2
0.5 - 1.8 7 - 26 440 68.2 2390 540
214/5
214/7
2
0.8 - 2.5 12 - 36 440 68.2 3400 760
221/8
0.8 - 1.7 12 - 25 940 146 7790 1750
45
221/8
221/12
32 -
1.2 - 2.5 17 - 36 940 146 11,700 2630
45
221/12
223/12
32
1.6 - 3.2 23 - 46 940 146 14,700 3300
221/8
0.9 - 1.7 13 - 25 910 141 8350 1880
221/8
221/12
- 1.125
1.4 - 2.5 20 - 36 910 141 12,500 2810
221/12
223/12
1.125
1.7 - 3.2 25 - 46 910 141 15,700 3530
221/8
0.7 - 1.6 10 - 23 870 135 6150 1380
45E
221/8
221/12
- 1.5
1.1 - 2.4 16 - 35 870 135 9230 2080
45E
221/12
223/12
1.5
1.3 - 3.1 19 - 45 870 135 11,500 2590
221/8
0.5 - 1.7 7 - 25 940 146 4740 1070
221/8
221/12
- 2
0.8 - 2.6 12 - 38 940 146 7110 1600
221/12
223/12
2
0.9 - 3.2 13 - 46 940 146 8800 1980
Note 1: Effective diaphragm area at 0% valve travel from seat.
Note 2: Based on zero operating pressure to the diaphragm and valve travel at 0% from valve seat. This does not consider limitations such as stem buckling load. Consult your Emerson
Process Management sales office for details.